ATS SOCOMEC - AN OVERVIEW

ATS Socomec - An Overview

ATS Socomec - An Overview

Blog Article

Possibility to set periodic genset startup Chance to set periodic genset startup ATyS p switches present additional functions for maintenance. They contain a programmable genset starting up purpose which will allow the setting up dates and functioning times to be configured.

They are intended for use in lower voltage ability methods the place interruption of your load supply is acceptable in the course of transfer.

Besides their built-in ability and Electrical power measurement capabilities (by using a 2% accuracy amount), programmable inputs/outputs is usually utilised to manage load shedding determined by a load degree or tariff.

Together with greater electrical performances, ATyS p supply a substantial standard of basic safety in the complete installation lifecycle.

Compact ATSE for easy integration in modular DIN enclosure, personalized transfer set up and preventive upkeep perform

Recording of situations ATyS p switches permit efficient checking of your set up thanks to timestamped celebration recording.

รับประกอบตู้ไฟฟ้า – ตู้ควบคุมทุกชนิด

Assure an ultimate redundancy for crisis gensets Back again up your entire distribution correct up towards the critical hundreds Sector Close

EN Source library has everything you will need that may help you website find the most effective electricity Alternative.

The ATyS g’s built-in controller has long been built to present distinct functions for these applications (genset startup, on-load or off-load checks…) together with the monitoring of your voltage and frequency of both equally sources for 3-period and single-section networks.The generator offer has to be connected to change II, Positioned on the rear.

The ATyS C66 can be an ATSE controller created to Command every type of crisis methods, legally demanded and optional standby transfer switching tools According to NEC (NFPA 70).

Safety and dependability ATyS p have the two electrical and mechanical interlocks for maximum security. The 0 position offers electrical safety disconnection and allows TSE lockout According to IEC60947-3.

จำหน่ายอุปกรณ์ไฟฟ้าแรงต่ำ-แรงสูงทุกชนิด อุปกรณ์ไฟฟ้าบ้าน อาคาร โรงงาน

ATyS C65 is a sophisticated ATSE controller providing all the features in the ATyS C55 Using the addition of present-day, electricity & Power checking, improved I/O capacity and features, load shedding, lift Regulate perform, energy backup, enhanced quantity of situations and alarms (measurement and mixture alarms) and DIRIS Digiware module compatibility.

The ATyS t’s integrated controller has become meant to offer only the features expected for these software (operation with or with out priority, chosen resource selection) together with the monitoring from the voltage and frequency of equally supply, for 3-period and one-section networks.

Report this page